I would like to warn programmer, that WCS and T-plane are different, so i added this into my post:
"string definition"
s_wcsnam s_tplnam
and in pparameter$ section
if prmcode$ = 20012, s_tplnam = sparameter$ if prmcode$ = 20014, s_wcsnam = sparameter$ [ if s_tplnam <> s_wcsnam, mprint("WCS-TPlane !!!)
]
but i get this error:
PST LINE (914) - The post block output type processing has failed!, , Label has not been defined[32] PST LINE (914) - The post block output type processing has failed!, , Illegal character(s) encountered PST LINE (914) - The post block output type processing has failed!, , Label was expected but was not found[51], Illegal character(s) encountered
I think that boolean <> is allowed for strings and result is 0 or 1. I tried many options how to fix this, but it still doesnt work. Pleas, can you help me?
And the next level is how to capture WCS origin coordinates and compare them to warn programmer.
These values are in OP_VIEW003 parameter 15366-15368, but i dont have this output in NCI.
Any Idea?